Barton BMC004 VC Master Clock/Divider (MOTM)

Out Of Stock Barton BMC004 VC Master Clock/Divider (MOTM)

 

Barton BMC004 VC Master Clock/Divider (MOTM)

 

New for the MOTM format in 2017!

module consists of the barton bmc004 master clock/divider and barton bmc040 dual logic pcbs

the bundle includes the panel, pcbs, PICs, and pcb mounting bracket (2 pot short bracket)

The master clock/divider BMC 004 uses two different types of controls, analog controls controls and digital controls. Analog controls are implemented with via knobs, external control voltages or a combination of the two. They present a finer degree of control than digital controls. Digital controls are implemented via switches or external gate or clock signals. They are either on or off with no middle ground.

A. TEMPO - The TEMPO control is an analog control. When the DIVIDER control is disengaged (see next section) the TEMPO control determines the frequency of the master clock which the dividers derive their frequencies from. When the DIVIDER control is disengaged, the tempo control is unused.

B. DIVIDER- This is a digital control, best implemented as a switch. When set off, the module acts as a master clock, and the RESET control acts as a reset. When set on, the module acts as a divider of an external clock and the RESET control acts as an input for an external clock.

C. RESET - This is a digital control, best implemented as a jack for external signals. When the module is acting as a master clock, a trigger or gate signal inputted to RESET will cause the master clock to reset, turning the internal counter back to zero and turning on all outputs. When the module is acting as a divider for external clocks the RESET is used as the input for the external clocks.

D. DIVISION1 through DIVISION6 - These are analog controls. In standard operation these select the level of frequency division used for each corresponding output. The levels of division available are 1, 2, 3, 4 , 5, 6, 7, 8, 16, 32, 64. In random operation DIVISION1 through DIVISION4 controls are repurposed and DIVISION5 and DIVISION6 are not used.

E.PWM1 through PWM4 - These are analog controls. Each of these controls the pulse width of the corresponding output.

F.RANDOM - This is a digital control. When set off, the module acts in it's normal mode. When set on, the module acts in random mode.

 

2.STANDARD CLOCK/DIVIDER MODE In standard mode, the modules outputs pulses whose frequencies are divided by a master frequency. In clock mode, this frequency is controlled by the TEMPO control, and in divider mode this frequency is controlled by the clock inputted to the RESET input. In clock mode a rising edge on the RESET input will reset the clock and dividers, setting all outputs high. Graph 1 illustrates the division of frequencies, showing all outputs having 50% pulse width. Pulse width is varied by the PWM controls for each output (not available if using 6 outputs). (Note: when changing divisions in any mode, new divisions are not recognized until after the output goes low, so when dealing with very high levels of division, there may be some delay when changing divisions) 

3.RANDOM CLOCK/DIVIDER MODE In random mode, PWM, RESET and TEMPO controls act identically as they did during standard mode, but the division of frequencies is no longer controlled by the DIVISION controls. Instead, frequency division is randomly selected and the DIVISION controls now control how often the division is selected and what levels of division are available. Each output has a re-roll counter which when it reaches zero causes that output to find a new random division. In Random clock mode, a trigger signal on the RESET input will cause new random divisions are reset all re-roll counters.

1.DIVISION1 now controls the re-roll counters lengths. The lengths available are 1, 2, 3, 4, 5, 6, 7, 8, 16, 32, and 64.

2.DIVISION2 now controls the input for the re-roll counters. When the analog voltage inputted is less then 2.5 volts each re-roll counter's input comes from it's corresponding output, thus each output's division will change at times which are not directly related to each other. When the analog voltage inputted to DIVISION2 is greater than 2.5 volts, each re-roll counter's input comes from the master clock frequency. This way division changes will sync up with one another.

3.DIVISION3 when set above 2.5 volts will allow only divisions which are square of two (2,4,8,16,32,64) to be selected.

4.DIVISION4 sets the maximum random division level

 

The BMC040 dual logic module provides two channels of selectable Boolean logic functions for processing synthesizer signals. Each channel has two inputs, “X” and “Y” and a single Gate output. The output is on or off depending on whether the voltages on the two inputs are above (“ON”) or below (“OFF”) 0.12V. This voltage was selected so that input voltages that alternated between 0 and 5V or signals that went from -5V to +5V could be used. There are six select able logic operations. When the operation select knob is fully counterclockwise the AND function is selected, and as the knob is turned clockwise it then selects NAND, OR, NOR, XOR and XNOR functions in that order. 

 

Module Parameters
FormatMOTM
Panel Size4U

Write a review

Please login or register to review
  • from $80.00 TO $125.00

Available Options

Options
Price
Available
Quantity
Discount
panel
Out of Stock - $80.00
 
 
pcb+panel+IC
Out of Stock - $125.00
 
 

Tags: barton, master, clock, divider, dual, logic, motm, pcb+panel, pcb, panel, bundles, modular, module bmc004+bmc040, clock/divider/dual, (motm), diy, synthesizer, kits, bartonclkdivlogmstr, michael musical, circuits